ATX20J3V1B / ARX20K5V1B9 ATX25J3V1B / ARX25K5V1B9 ATX35J3V1B / ARX35K5V1B9
Indoor unit ATX20J3 ATX25J3 ATX35J3
Outdoor unit ARX20K ARX25K ARX35K
Aušinimo galingumas Min. kW 1.3 1.3 1.3
  Min. Btu/h 4,400 4,400 4,400
  Min. kcal/h 1,120 1,120 1,120
  Nom. kW 2.0 (2) 2.5 (2) 3.3 (2)
  Nom. Btu/h 6,800 (2) 8,500 (2) 11,300 (2)
  Nom. kcal/h 1,720 (2) 2,150 (2) 2,840 (2)
  Maks. kW 2.6 3.0 3.8
  Maks. Btu/h 8,900 10,200 13,000
  Maks. kcal/h 2,240 2,580 3,270
Šildymo galingumas Min. kW 1.3 1.3 1.3
  Min. Btu/h 4,400 4,400 4,400
  Min. kcal/h 1,120 1,120 1,120
  Nom. kW 2.5 (2) 2.8 (2) 3.5 (2)
  Nom. Btu/h 8,500 (2) 9,600 (2) 11,900 (2)
  Nom. kcal/h 2,150 (2) 2,410 (2) 3,010 (2)
  Maks. kW 3.5 4.0 4.8
  Maks. Btu/h 11,900 13,600 16,400
  Maks. kcal/h 3,010 3,440 4,130
Tiekiamas galingumas Aušinimas Min. kW 0.310 0.310 0.290
    Nom. kW 0.490 (2) 0.700 (2) 1.030 (2)
    Maks. kW 0.720 1.050 1.300 (2)
  Šildymas Min. kW 0.250 0.250 0.290
    Nom. kW 0.590 (2) 0.690 (2) 0.930 (2)
    Maks. kW 0.950 1.110 1.290
Vardinis našumas EER   4.09 (1) 3.55 (1) 3.21 (1)
  COP   4.24 (1) 4.06 (1) 3.76 (1)
  Metinis energijos sunaudojimas kWh 244 (0.000) 352 (0.000) 514 (0.000)
  Energijos suvartojimo ženklinimo direktyva Vėsinimas   A A A
    Šildymas   A A A
Sezoninis efektyvumas (pagal EN14825) Vėsinimas Energijos efektyvumo klasė   A++ A++ A++
    Pdesign kW 2.00 2.50 3.30
    SEER   6.11 6.15 6.15
    Energijos suvartojimas per metus kWh 115 142 188
    A sąlyga (35 °C – 27/19) Pdc kW 2.00 2.50 3.30
      EERd   4.09 3.55 3.21
      galios įvestis kW 0.49 0.70 1.03
    B sąlyga (30 ℃ – 27/19) Pdc kW 1.56 1.84 2.43
      EERd   5.83 5.27 5.55
      galios įvestis kW 0.27 0.35 0.44
    C sąlyga (25 ℃ – 27/19) Pdc kW 1.22 1.22 1.60
      EERd   7.55 7.80 6.98
      galios įvestis kW 0.16 0.16 0.23
    D sąlyga (20 ℃ – 27/19) Pdc kW 1.15 1.15 1.20
      EERd   9.46 9.20 9.91
      galios įvestis kW 0.12 0.13 0.12
  Šildymas (vidutinis klimatas) Energijos efektyvumo klasė   A+ A+ A+
    Pdesign kW 2.20 2.40 2.80
    SCOP   4.34 4.16 4.14
    SCOPnet   4.40 4.21 4.19
    Energijos suvartojimas per metus kWh 711 809 947
    Reikia atsarginio šildymo paj. projektavimo sąlygomis kW 0.39 0.43 0.50
    TOL Tol (temperatūros darbinis limitas) °C -15 -15 -15
      Pdh (nurodytas šildymo paj.) kW 1.59 1.72 1.99
      COPd (nurodytas COP)   2.46 2.31 2.12
      Galios įvestis kW 0.65 0.74 0.94
    TBivalent Tbiv (bivalentinė temperatūra) °C -7 -7 -7
      Pdh (nurodytas šildymo paj.) kW 1.95 2.13 2.48
      COPd (nurodytas COP)   2.76 2.50 2.24
      Galios įvestis kW 0.71 0.85 1.11
    A sąlyga (-7 ℃) Pdh (nurodytas šildymo paj.) kW 1.95 2.13 2.48
      COPd (nurodytas COP)   2.76 2.50 2.24
      Galios įvestis kW 0.71 0.85 1.11
    B sąlyga (2 ℃) Pdh (nurodytas šildymo paj.) kW 1.18 1.29 1.51
      COPd (nurodytas COP)   4.45 4.19 4.31
      Galios įvestis kW 0.27 0.31 0.35
    C sąlyga (7 ℃) Pdh (nurodytas šildymo paj.) kW 0.90 0.89 1.00
      COPd (nurodytas COP)   5.70 5.61 5.60
      Galios įvestis kW 0.16 0.16 0.18
    D sąlyga (12 ℃) Pdh (nurodytas šildymo paj.) kW 1.02 1.02 1.10
      COPd (nurodytas COP)   6.85 6.74 6.86
      Galios įvestis kW 0.15 0.15 0.16
Pto (Thermostat off) W 30.0 30.0 30.0
Vėsinimas Psb (vėsinimas budėjimo režimu) W 1.0 1.0 1.0
  Cdc (nykstamasis vėsinimas)   0.25 0.25 0.25
Šildymas Cdh (nykstamasis šildymas)   0.25 0.25 0.25
Pck (karterio šildytuvo režimas) W 0.0 0.0 0.0
Poff (išjungimo režimas) W 1.0 1.0 1.0
Įtraukiama vėsinimo funkcija Taip Taip Taip
Įtraukiama šildymo funkcija Taip Taip Taip
Numatomas vidutinis klimatas Taip Taip Taip
Numatomas šaltas sezonas Ne Ne Ne
Numatomas šiltas sezonas Ne Ne Ne
Vamzdžių jungtys Drenažo vamzdis OD mm 18 18 18
  Dujų vamzdis OD mm 9.5 9.5 9.5
  Šilumos izoliacija   Skysčio ir dujų vamzdžiai Skysčio ir dujų vamzdžiai Skysčio ir dujų vamzdžiai
  Liquid OD mm 6.35 6.35 6.35
Srovė Nominalioji darbinė srovė – 50Hz Aušinimas A 2.4 3.6 5.5
    Šildymas A 3.0 3.2 4.7
Pastabos EER/COP pagal „Eurovent 2012“, skirta naudoti tik už ES ribų EER/COP pagal „Eurovent 2012“, skirta naudoti tik už ES ribų EER/COP pagal „Eurovent 2012“, skirta naudoti tik už ES ribų
  Nominalus efektyvumas: vėsinimas esant 35°/27° nominaliąja apkrova, šildymas esant 7°/20° nominaliąja apkrova Nominalus efektyvumas: vėsinimas esant 35°/27° nominaliąja apkrova, šildymas esant 7°/20° nominaliąja apkrova Nominalus efektyvumas: vėsinimas esant 35°/27° nominaliąja apkrova, šildymas esant 7°/20° nominaliąja apkrova